Learn › Physics Entrepreneurship
Worked design calculations
Free preview Lesson 16 of 60
perform design calculations for a cook-stove, solar pump, cold room, evaporative cooler and off-grid solar system.
Example 1: Energy-efficient cook-stove
How much wood is needed to bring 2.0 kg of water from 25 °C to 100 °C, on an open fire (25 per cent efficient) and on an improved stove (40 per cent efficient)? Take the specific heat capacity of water as 4200 J/(kg K) and the calorific value of dry wood as 15 MJ/kg. Neglect evaporation.
Q = m c ΔT = 2.0 × 4200 × (100 − 25) = 630 000 J = 0.63 MJ
Open fire: energy needed from the fuel = 0.63 ÷ 0.25 = 2.52 MJ, so the mass of wood is 2.52 ÷ 15 = 0.168 kg. Improved stove: 0.63 ÷ 0.40 = 1.575 MJ, so the mass is 1.575 ÷ 15 = 0.105 kg. The saving is (0.168 − 0.105) ÷ 0.168 = 0.375, or 37.5 per cent of the fuel per boil. For a household that cooks for several hours daily, this reduction translates into a monthly saving in fuel cost that can be used in the sales argument.
Example 2: Solar pump sizing
A farmer needs to lift 5.0 m³ of water per hour through a total head of 20 m. The overall pump efficiency is 50 per cent. Estimate the electrical power required (ρ = 1000 kg/m³, g = 9.81 m/s²).
P(hydraulic) = ρ g Q h, and P(electrical) = P(hydraulic) ÷ η
Flow rate Q = 5.0 ÷ 3600 = 1.389 × 10⁻³ m³/s. Hydraulic power = 1000 × 9.81 × 1.389 × 10⁻³ × 20 = 272.5 W. Electrical power = 272.5 ÷ 0.50 = 545 W. A solar array of about 700 to 800 W peak, allowing for losses and cloud, and a controller matched to the pump would therefore be a reasonable first design.
Example 3: Insulation of a small cold room
The walls of a cold room have total area 20 m², are made of polystyrene panels of thickness 0.10 m and thermal conductivity k = 0.040 W/(m K). The inside temperature is 5 °C and the outside temperature is 30 °C. Estimate the heat flow through the walls.
Q̇ = k A ΔT ÷ d = 0.040 × 20 × 25 ÷ 0.10 = 200 W
The refrigeration unit must therefore remove at least 200 W continuously from wall conduction alone, in addition to heat from the produce, door opening and lighting. Doubling the thickness to 0.20 m halves this load to 100 W, and the extra cost of panels can be compared with the electricity saved, which is a typical design trade-off.
Example 4: Evaporative cooling
A clay-pot cooler evaporates 0.10 kg of water. Estimate the temperature drop of 5.0 kg of vegetables of specific heat capacity 3600 J/(kg K), assuming all the latent heat (L = 2.26 × 10⁶ J/kg) is drawn from the vegetables.
ΔT = m(water) L ÷ (m(veg) c) = (0.10 × 2.26 × 10⁶) ÷ (5.0 × 3600) = 12.6 K
This is an upper limit, since heat also enters from the surroundings, but it explains why such coolers can extend the shelf life of vegetables at almost no running cost. The same calculation shows why they are less effective in the humid rainy season, when evaporation is slow.
Example 5: Sizing an off-grid solar system
A small shop has the following daily load.
- 4 LED bulbs (10 W each): 40 W for 5 hours = 200 Wh/day.
- Television: 60 W for 4 hours = 240 Wh/day.
- Fan: 50 W for 6 hours = 300 Wh/day.
- Phone charging: 20 W for 1 hour = 20 Wh/day.
- Total: 170 W and 760 Wh/day.
Now size the system step by step.
- Corrected daily energy (allowing 30 per cent for wiring, controller, battery and inverter losses): 760 × 1.3 = 988 Wh/day.
- Panel size: assume 5.0 peak sun hours per day for Lafia. Panel power = 988 ÷ 5.0 = 197.6 W, so a 200 W panel (or two 100 W panels) is chosen.
- Battery capacity: system voltage 12 V, one day of autonomy, 50 per cent maximum depth of discharge for lead-acid. Capacity = 988 ÷ (12 × 0.50) = 164.7 Ah, so two 100 Ah, 12 V batteries in parallel (200 Ah) are chosen.
- Inverter: the largest simultaneous load is 40 + 60 + 50 + 20 = 170 W. Applying a 25 per cent margin gives 212.5 W; a 300 W pure-sine inverter is selected to also allow for start-up surge.
- Controller: panel current at 12 V ≈ 200 ÷ 12 = 16.7 A; a 20 A charge controller is chosen (a 30 A unit gives growth room).
Such a calculation is the technical core of a solar installation business. The commercial skill lies in explaining it to the customer, pricing the components, and guaranteeing performance.
You are viewing a free preview. Enrol to unlock the rest of the course and track your progress.